High performance photon counting camera to improve resolution of RIXS experiments
RIXSCam enables single-photon detection with exceptional spatial and energy resolution for scientists and researchers in the field of synchrotron radiation and x-ray spectroscopy; specifically, those conducting Resonant Inelastic X-ray Scattering (RIXS) experiments.
Features & Benefits
- Soft X-ray Detection (250 - 3000 eV): enables experiments across a broad range of soft x-ray energies, suitable for diverse material and chemical studies.
- Exceptional <5 μm Spatial Resolution: provides highly detailed imaging and precise mapping of x-ray interactions for improved experimental accuracy.
- Single Photon Detection: detects extremely low-intensity signals, increasing sensitivity and enabling studies of weak phenomena.
- Sub-Electron Read Noise: reduces measurement noise, enhancing signal clarity and reliability of results.
- User-Controlled Effective Pixel Size: allows optimisation of spatial and energy resolution for specific beamline requirements.
- Variable Detector Angle of Incidence: improves spatial and energy resolution by adjusting the detector orientation to the x-ray beam.
- Large Detector Area: captures multiple photons simultaneously, increasing throughput and reducing experiment time.
- XHV-Compatible Manufacture: ensures compatibility with ultra-high vacuum environments typical of synchrotron beamlines and cryogenic operation.
- Up to 3 Back-illuminated EMCCD Detectors: increases photon collection efficiency and overall data quality, supporting high-throughput experiments.
- Customisable to Individual Requirements: modular design adapts to unique experimental setups, providing flexibility for cutting-edge research needs.
Applications
- Resonant Inelastic X-ray Scattering (RIXS) Experiments: high resolution mapping of electronic excitations in materials
- Synchrotron Radiation Experiments: studies requiring precise detection of soft x-rays
Multi-EMCCD Large Detector Area System
The RIXSCam system was originally designed in collaboration with scientists at the Paul Scherrer Institute (PSI) for the Swiss Light Source ADRESS beamline. Utilising EMCCDs it enables single photon detection, increasing the intensity of photons detected, and operates 3x faster than previous systems while maintaining <1 e- RMS noise.
Centroiding technology combined with a unique algorithm developed by Paul Scherrer Institute gives this vacuum compatible camera an unbeatable spatial resolution, allowing energy to be resolved to an unprecedented degree. The rotatable detector bench, which holds up to three detectors, allows the operator to foreshorten the effective pixel size by changing the angle of incidence with the beam to further improve resolution.
RIXSCam builds on XCAM Scientific’s tradition of collaborative design, catering to the individual needs of customers who are working to the most demanding requirements, particularly where there is no existing solution available.
Key Specifications
- Maximum Active Area: 78.33 x 25.73 mm
- Active Pixels (H x V): 4896 x 1608
- Pixel Size: 16 x 16 μm
- Readout Rate: 3 MHz
- Post-processed Resolution: < 5 μm
- System Noise - With Gain: ≤ 1 e-
- System Noise - No Gain: ≤ 140 e-
- Detector Incidence Angle: 20° to 90°
- Vacuum Compatibility: 10⁻⁹ mbar
- Temperature Control: -110°C to -50°C